Communications Setup

 

9120 - Communications Setup

 

This menu option will allow the user to determine how the Touchscreen will communicate with the 9120 instrument.

 

The Media option will be the type of connection the Touchscreen is using to connect to the 9120.  The options are:

  • COM1

  • COM2

  • COM3

  • COM4

  • Ethernet

     

If COM1 through COM4 is selected, the user will have to set the Address and the Baud rate as well.  If Ethernet is selected, then user will have to enter the IP address of the 9120 instrument

 

The Address option is the Client address of the 9120 instrument for the COM port communications, or the Ethernet IP address for Ethernet communications.  For the COM port communications, the address will range from 1 to 250.  For Ethernet communications, the address must be supplied in a 999.999.999.999 format, or it will not be accepted.

The Baud option is the baud rate for the COM port communications.  The options are:

  • 1200

  • 2400

  • 4800

  • 9600

  • 14400

  • 19200

  • 28800

  • 38400

  • 57600

  • 76800

  • 115200